The effect of changing vertical irradiation angle of periapical radiography bisecting technique on the length dimension of mandibular teeth
Abstract
Objectives: This research is aimed to determine the effect of changing the vertical irradiation angle with a change in angle of +10°, +5°, -5°, -10° in bisecting technique periapical radiography on the length dimension of mandibular teeth.Materials and Methods: This study used a laboratory experimental method with a post test only control group design. The samples used in this study were teeth I1, I2, C, P1, P2, M1, and M2 region 4. All teeth were treated by changing the angle from the standard angle recommended by White and Pharoah with changes of +10°, +5°, -5°, and -10° in each tooth using a Morita Veraview iX 70 Kv, 7mA dental X-ray unit.
Results: The results showed that the angle change of -10°, -5° causes foreshortening and +10°, +5° causes elongation. Based on the results of the Saphiro-Wilk and Kruskal-Wallis test, it is known that there are significant differences in the dimensions of tooth length at +10°, +5°, -5°, -10° against changes in the angle 0° or angulation form White and Pharoah (p < 0.05) .
Conclusion: There is a significant effect on the change of vertical irradiation angle with angle changes of +10°, +5°, -5°, -10° in bisecting technique periapical radiography on the length dimension of mandibular teeth.
References
Raidha F, Epsilawati L, Wardani R. Pengetahuan radiografi di bidang kedokteran gigi pada siswa Sekolah Menengah Atas. Padjadjaran J Dent Res Stud. 2018;2(2):150-4.
Ramadhan AZ, Sitam S, Azhari A, Epsilawati L. Gambaran kualitas dan mutu radiograf. J Radiol Dentomaksilofasial Indones JRDI. 2020;3(3):43-8.
Carestream Dental. Dental Radiography Series. Carestream Heal; 2016. p.3.
Permatahati A, Firman RN, Pramanik F. Kualitas radiograf periapikal dengan teknik bisektrisThe quality periapical radiograph with the bisecting technique. Padjadjaran J Dent Res Stud. 2019;3(2):82-6.
Dayo AF, Wolff MS, Syed AZ, Mupparapu M. Radiology of Dental Caries. Dent Clin North Am. 2021;65(3):428-30.
Whaites E, Drage N. Essentials of Dental Radiography and Radiology E-Book. 6th edition. Amsterdam: Elsevier; 2020. p.206-32.
Mallya SM, Lam EWN, White SC, Pharoah MJ. White and Pharoah’s oral radiology: principles and interpretation. 8th edition. St. Louis, Missouri: Elsevier; 2019. p.659.
Primazetyarini AS, Suryonegoro H, Syahraini SI. Tolerance of vertical angle alteration on lower molar periapical radiographs in the laboratory. J Phys Conf Ser. 2018;1073:022009.
Anggara A, Iswani R, Darmawangsa D. Perubahan Sudut Penyinaran Vertikal pada Bisecting Tecnique Radiography Terhadap Keakuratan Dimensi Panjang Gigi Premolar Satu Atas. B-Dent J Kedokt Gigi Univ Baiturrahmah. 2019;5:1–8.
Antolis M, Priaminiarti M, Kiswanjaya B. Vertical Angulation Alteration Tolerance in the Periapical Radiograph of Maxillary Incisor (An in vitro Study). J Dent Indones. 2014;21:39–43.
Oakley PA, Harrison DE. Death of the ALARA Radiation Protection Principle as Used in the Medical Sector. Dose-Response. 2020;18:155932582092164.
Williamson GF. Intraoral Radiography: Positioning and Radiation Protection. Protection. J Dent. 2014;1(5):38.
Bilhan H, Geçkili O, Arat Bilhan S, Ayçiçek F, Albayrak B, Bozbulut P, et al. The Comparison of the Presicion of Different Dental Radiographic Methods in Mandibular Peri-Implantary Measurment: An In Vitro Study. J Istanb Univ Fac Dent. 2015;49(1):1-9.
Reski MA, Sugianto I. Identifikasi Kesalahan Radiografi Periapikal Digital Teknik Bisecting: Literature Review. Sinnun Maxillofac J. 2022;4:104–12.
Kusumawati KY, Yanuaryska RD, Shantiningsih RR. The accuracy of extraoral periapical radiography on determining the working length in endodontic treatment: narrative review. J Radiol Dentomaksilofasial Indones JRDI. 2022;6(1):41-8.
Ramadhan AZ, Sitam S, Azhari A, Epsilawati L. Gambaran kualitas dan mutu radiograf. J Radiol Dentomaksilofasial Indones JRDI. 2020;3(3):43-8.
Carestream Dental. Dental Radiography Series. Carestream Heal; 2016. p.3.
Permatahati A, Firman RN, Pramanik F. Kualitas radiograf periapikal dengan teknik bisektrisThe quality periapical radiograph with the bisecting technique. Padjadjaran J Dent Res Stud. 2019;3(2):82-6.
Dayo AF, Wolff MS, Syed AZ, Mupparapu M. Radiology of Dental Caries. Dent Clin North Am. 2021;65(3):428-30.
Whaites E, Drage N. Essentials of Dental Radiography and Radiology E-Book. 6th edition. Amsterdam: Elsevier; 2020. p.206-32.
Mallya SM, Lam EWN, White SC, Pharoah MJ. White and Pharoah’s oral radiology: principles and interpretation. 8th edition. St. Louis, Missouri: Elsevier; 2019. p.659.
Primazetyarini AS, Suryonegoro H, Syahraini SI. Tolerance of vertical angle alteration on lower molar periapical radiographs in the laboratory. J Phys Conf Ser. 2018;1073:022009.
Anggara A, Iswani R, Darmawangsa D. Perubahan Sudut Penyinaran Vertikal pada Bisecting Tecnique Radiography Terhadap Keakuratan Dimensi Panjang Gigi Premolar Satu Atas. B-Dent J Kedokt Gigi Univ Baiturrahmah. 2019;5:1–8.
Antolis M, Priaminiarti M, Kiswanjaya B. Vertical Angulation Alteration Tolerance in the Periapical Radiograph of Maxillary Incisor (An in vitro Study). J Dent Indones. 2014;21:39–43.
Oakley PA, Harrison DE. Death of the ALARA Radiation Protection Principle as Used in the Medical Sector. Dose-Response. 2020;18:155932582092164.
Williamson GF. Intraoral Radiography: Positioning and Radiation Protection. Protection. J Dent. 2014;1(5):38.
Bilhan H, Geçkili O, Arat Bilhan S, Ayçiçek F, Albayrak B, Bozbulut P, et al. The Comparison of the Presicion of Different Dental Radiographic Methods in Mandibular Peri-Implantary Measurment: An In Vitro Study. J Istanb Univ Fac Dent. 2015;49(1):1-9.
Reski MA, Sugianto I. Identifikasi Kesalahan Radiografi Periapikal Digital Teknik Bisecting: Literature Review. Sinnun Maxillofac J. 2022;4:104–12.
Kusumawati KY, Yanuaryska RD, Shantiningsih RR. The accuracy of extraoral periapical radiography on determining the working length in endodontic treatment: narrative review. J Radiol Dentomaksilofasial Indones JRDI. 2022;6(1):41-8.
Published
2024-04-30
How to Cite
WIJAYA, Andrew Sebastian; LUBIS, Muhammad Novo Perwira Satria.
The effect of changing vertical irradiation angle of periapical radiography bisecting technique on the length dimension of mandibular teeth.
Jurnal Radiologi Dentomaksilofasial Indonesia (JRDI), [S.l.], v. 8, n. 1, p. 13-18, apr. 2024.
ISSN 2686-1321.
Available at: <http://jurnal.pdgi.or.id/index.php/jrdi/article/view/1140>. Date accessed: 23 nov. 2024.
doi: https://doi.org/10.32793/jrdi.v8i1.1140.
Section
Original Research Article
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.